Parts needed:
- Approximately 60" of clear 3/8" flexible plastic (vinyl) tubing.
- Staples or tie straps to hold tubing to back plate.
- 6" x 16" wood board or sheet metal.
- Ruler.
2.) At about the midway point of the tubing, mark the back board with a zero location.
3.) From the zero location, place marks every 1/2" above and below. Number the marks every one inch. Place a target arrow mark at 5 1/2" on top and bottom. This target will equal 11 inches of water column (W.C.).Monometer to test gas pressure
To test gas pressure:
1.) Fill the Manometer "U" tubing with water until both sides reach zero.
2.) Connect free end of tubing to the gas supply line. A slip fit or hand held fit should be sufficient. Be sure it does not leak.
3.) Hold the Manometer vertical and slowly turn the gas supply on.
4.) The pressure will push the water down the input side and up the output side. The combined sum of both distances is the "inches of water column pressure". The target is 5 1/2" + 5 1/2" = 11 inches of W.C.
5.) Most high quality regulators will have an adjustment screw usually covered with a plug or plastic screw cap. Turn the adjuster screw slightly and repeat steps 3 & 4 until 11" W.C. is achieved.
To learn more about gas refrigerators contact warehouse appliance at 928-636-1955 or visit our website at http://www.warehouseappliance.com.